222-10NB6-2221895
Switches
SWITCH,PRESSURE
222-10NB6-2221895
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Load Current Rating
3.2 amperes inductive load first voltage
-
Contact Adjustment Range
+10.00/+180.00 actuation point pounds per square inch gage and +10.00/+180.00 deactuation point pounds per square inch gage
-
Thread Series Designator
unf single pressure connection
-
Shortest Horizontal Distance Between Mounting Centers
0.656 inches nominal
-
Contact Adjustability
deactuation point adjustable and actuation point adjustable
-
Mounting Method
bracket and unthreaded hole
-
Contact Load Current Rating
16.0 amperes inductive load second voltage
-
Contact Voltage Rating In Volts
115.0 dc at sea level fourth voltage
-
Overall Width
2.812 inches nominal
-
Mounting Facility Pattern
isosceles triangle
-
Contact Load Current Rating
2.0 amperes inductive load third voltage
-
Contact Adjustment Type
external deactuation point screw and external actuation point screw
-
Contact Voltage Rating In Volts
550.0 ac at sea level first voltage
-
Terminal Type
tab w/screw
-
Unthreaded Mounting Hole Diameter
0.281 inches nominal
-
Longest Horizontal Distance Between Mounting Centers
2.406 inches nominal
-
Style Designator
rectangular
-
Media For Which Designed
gas or liquid
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Contact Voltage Rating In Volts
115.0 ac at sea level second voltage
-
Contact Load Current Rating
9.6 amperes inductive load fourth voltage
-
Nominal Thread Size
0.438 inches single pressure connection
-
Features Provided
electrical access port
-
Body Height
2.750 inches nominal
-
Longest Vertical Distance Between Mounting Centers
3.281 inches nominal
-
Pressure Switch Type
gage
-
Contact Voltage Rating In Volts
550.0 dc at sea level third voltage
-
Overall Length
5.188 inches nominal
-
Thread Class
2b single pressure connection
-
Pressure Connector Type
plain, threaded internal single connection
-
Thread Quantity Per Inch
20 single pressure connection
-
Contact Action Stimulus
increase