Technical Characteristics

  • Temp Points For Resistance Readings At Zero Power

    -60.0 deg celsius 1st resistance-temperature point

  • Terminal Type And Quantity

    2 wire lead

  • Reliability Indicator

    not established

  • Zero Power Resistance At Specified Temp

    163.7 kilohms 3rd resistance-temperature point

  • Zero Power Resistance Tolerance In Percent At Reference Temp

    -20.0/+20.0

  • Resistance Tolerance At A Specified Temp In Percent

    -25.5/+25.5 6th resistance-temperature point

  • Inclosure Type

    encapsulated

  • Temp Points For Resistance Readings At Zero Power

    200.0 deg celsius 9th resistance-temperature point

  • Terminal Diameter

    0.012 inches nominal

  • Zero Power Resistance

    50.000 kilohms

  • Zero Power Resistance At Specified Temp

    7.3 megohms 1st resistance-temperature point

  • Style Designator

    probe

  • Resistance Tolerance At A Specified Temp In Percent

    -26.2/+26.2 2nd resistance-temperature point

  • Terminal Length

    2.000 inches nominal

  • Zero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius

    -4.40

  • Terminal Surface Treatment

    solder

  • Resistance Tolerance At A Specified Temp In Percent

    -27.4/+27.4 7th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -31.5/+31.5 9th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -22.5/+22.5 3rd resistance-temperature point

  • Power Dissipation Constant In Milliwatts Per Deg Celsius

    1.7

  • Probe Diameter

    0.100 inches maximum

  • Resistance Tolerance At A Specified Temp In Percent

    -35.0/+35.0 10th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -23.3/+23.3 5th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    120.0 deg celsius 7th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    40.3 kilohms 4th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    12.4 kilohms 5th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    330.0 ohms 9th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    896.000 kilohms 2nd resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    -30.0 deg celsius 2nd resistance-temperature point

  • Zero Power Resistance At Specified Temp

    85.0 ohms 10th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    300.0 deg celsius 10th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    90.0 deg celsius 6th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    0.0 deg celsius 3rd resistance-temperature point

  • Probe Length

    0.500 inches nominal

  • Resistance Tolerance At A Specified Temp In Percent

    -30.9/+30.9 1st resistance-temperature point

  • Zero Power Resistance At Specified Temp

    4.6 kilohms 6th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -20.7/+20.7 4th resistance-temperature point

  • Reference Temp In Deg Celsius

    25.0

  • Temp Points For Resistance Readings At Zero Power

    30.0 deg celsius 4th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    150.0 deg celsius 8th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -29.2/+29.2 8th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    921.5 ohms 8th resistance-temperature point

  • Thermal Time Constant In Seconds

    22.0

  • Temp Points For Resistance Readings At Zero Power

    60.0 deg celsius 5th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    1.9 kilohms 7th resistance-temperature point

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...