9063052

Circuit Breakers

CIRCUIT BREAKER

9063052

5925-00-050-8501

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.031 inches nominal

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    3.063 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Boss Height

    0.156 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Mounting Surface To Terminal End Distance

    3.454 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.300 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Manual Actuator Type And Quantity

    3 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.031 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1300.0 ac all locations

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Body Length

    3.719 inches nominal

  • Reset Method

    manual

  • Body Width

    3.063 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    416.0 ac all locations

  • Thread Series Designator

    unc

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...