NJ9K-20183

Switches

SWITCH,PRESSURE

NJ9K-20183

5930-00-051-1334

5930 - Switches

United Electric Controls Company

SWITCH,PRESSURE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Contact Adjustment Type

    external deactuation point screw and external actuation point screw

  • Contact Voltage Rating In Volts

    550.0 ac at sea level first voltage

  • Contact Adjustment Range

    +4.00/+35.00 actuation point pounds per square inch and +4.00/+35.00 deactuation point pounds per square inch

  • Inside Diameter

    0.250 inches nominal single connection

  • Unthreaded Mounting Hole Diameter

    0.281 inches nominal

  • Contact Load Current Rating

    3.2 amperes inductive load first voltage

  • Thread Series Designator

    npt all pressure connection

  • Overall Width

    2.688 inches nominal

  • Terminal Type

    screw

  • Style Designator

    rectangular

  • Thread Quantity Per Inch

    18 all pressure connection

  • Media For Which Designed

    gas or liquid

  • Proof Pressure

    80.00 pounds per square inch gage

  • Nonpile-Up Contact Arrangement

    1 pole, single throw, normally closed, momentary action

  • Pressure Connector Type

    plain, threaded internal all connections

  • Contact Voltage Rating In Volts

    115.0 ac at sea level second voltage

  • Contact Load Current Rating

    9.6 amperes inductive load fourth voltage

  • Features Provided

    electrical access port

  • Pressure Switch Type

    differential

  • Distance Between Mounting Facility Centers

    5.250 inches nominal

  • Body Length

    4.750 inches nominal

  • Body Height

    2.750 inches nominal

  • Contact Voltage Rating In Volts

    550.0 dc at sea level third voltage

  • Nominal Thread Size

    0.250 inches single pressure connection

  • Mounting Facility Pattern

    two position in-line

  • Contact Action Stimulus

    increase

  • Overall Length

    5.500 inches nominal

  • Contact Adjustability

    deactuation point adjustable and actuation point adjustable

  • Contact Load Current Rating

    16.0 amperes inductive load second voltage

  • Contact Voltage Rating In Volts

    115.0 dc at sea level fourth voltage

  • Mounting Method

    flange and unthreaded hole

  • Overall Height

    7.563 inches nominal

  • Contact Load Current Rating

    2.0 amperes inductive load third voltage

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...