DMS83059

Circuit Breakers

CIRCUIT BREAKER

DMS83059

5925-00-051-4889

5925 - Circuit Breakers

Defense Electronics Supply Center

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.180 inches minimum and 1.200 inches maximum

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and explosion proof and vibrationproof

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    2 screw

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac single location

  • Mounting Surface To Terminal End Distance

    1.990 inches minimum and 2.010 inches maximum

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.802 inches minimum and 1.822 inches maximum

  • Frequency In Hertz

    400.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    19.000 minimum at 200 pct single location and 65.000 maximum at 200 pct single location

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...