P-S-308
Switches
SWITCH,PRESSURE
P-S-308
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Series Designator
npt single pressure connection
-
Contact Voltage Rating In Volts
460.0 ac at sea level second voltage
-
Contact Stimulus Rating
0.11 differential point nominal pound
-
Thread Quantity Per Inch
18 single pressure connection
-
Contact Load Current Rating
3.0 amperes resistive load second voltage
-
Contact Voltage Rating In Volts
125.0 ac at sea level first voltage
-
Nonpile-Up Contact Arrangement
2 pole, double throw, both positions maintained
-
Contact Load Current Rating
10.0 amperes resistive load first voltage
-
Pressure Switch Type
gage
-
Distance Between Mounting Facility Centers
2.250 inches nominal
-
Mounting Method
bracket
-
Nominal Thread Size
0.250 inches single pressure connection
-
Mounting Facility Pattern
two position in-line