5003-3104
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
5003-3104
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.000 inches nominal
-
Operating Voltage Rating And Type Per Function
125.0 volts ac 2nd radio interference 2nd function
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.164 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.000 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Features Provided
nut and shock resistant
-
Inclosure Type
hermetically sealed
-
Maximum Voltage Drop Per Function
3.0 volts ac 3rd radio interference
-
Functional Terminal Type And Quantity
4 threaded stud output 2nd function
-
Mounting Facility Type And Quantity
4 threaded stud
-
Maximum Temp Rise
20.0 deg celsius
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Operating Voltage Rating And Type Per Function
125.0 volts ac 3rd radio interference 3rd function
-
Maximum Voltage Drop Per Function
1.5 volts ac 2nd radio interference
-
Maximum Voltage Drop Per Function
0.5 volts dc 4th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Full Load Insertion Loss Frequencies In Megahertz
200.0 and 100.0 and 0.15 and 1.0 and 10.0 and 400.0
-
Operating Current Rating Per Function In Amps
1.5 1st radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Maximum Voltage Drop Per Function
0.5 volts ac 1st radio interference
-
Operating Current Rating Per Function In Amps
1.5 2nd radio interference
-
Operating Current Rating Per Function In Amps
1.5 3rd radio interference
-
Body Material
metal
-
Operating Current Rating Per Function In Amps
1.5 4th radio interference
-
Body Width
4.000 inches nominal
-
Special Features
four filtered funcions
-
Overall Height
2.700 inches nominal
-
Functional Terminal Type And Quantity
4 threaded stud input 1st function
-
Style Designator
rectangular terminal/terminals on one surface
-
Operating Temp Range
+0.0/+55.0 deg celsius
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Body Length
4.000 inches nominal
-
Maximum Dielectric Withstanding Dc Voltage
500.0 volts at sea level
-
Operating Voltage Rating And Type Per Function
30.0 volts dc 4th radio interference 4th function
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Body Height
1.500 inches nominal
-
Vibration Resistance Range In Hertz
+5.0/+55.0
-
Full Load Minimum Insertion Loss At Specified Frequency In Decibels
90.0 and 75.0 and 100.0 and 100.0 and 100.0 and 90.0
-
Operating Voltage Rating And Type Per Function
125.0 volts ac 1st radio interference 1st function
-
Load Impedance Per Function
50.0 ohms 4th radio interference