1500-022-1

Circuit Breakers

CIRCUIT BREAKER

1500-022-1

5925-00-053-3536

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    1.843 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.900 minimum at 200 pct single location and 4.900 maximum at 200 pct single location

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location and 4.0 amperes dc single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Width

    0.750 inches maximum

  • Bushing Length

    0.235 inches minimum and 0.265 inches maximum

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Special Features

    phantom f-4 and other aircraft weapons systems

  • Center To Center Distance Between Terminals Parallel To Length

    0.685 inches minimum and 0.715 inches maximum

  • Fragility Factor

    moderately rugged

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Criticality Code Justification

    feat

  • Actuator Function

    trip-reset

  • Body Length

    1.122 inches minimum and 1.152 inches maximum

  • Manual Actuator Type And Quantity

    1 push button

  • Unpackaged Unit Weight

    0.100 pounds

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    explosion proof

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    600.0 ac single location and 6000.0 dc single location

  • Frequency In Hertz

    400.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...