Circuit Breakers
CIRCUIT BREAKER
SM333HHK7-5-240VAC400C1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 150 pct all locations and 15.000 maximum at 150 pct all locations
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Reset Method
manual
-
Auxiliary Switch Function And Quantity
2 control
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Actuator Function
trip-reset
-
Mounting Surface To Terminal End Distance
1.678 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac all locations
-
Actuator Position Designation
at pole two
-
Body Length
1.495 inches nominal
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Switch Contact Arrangement
single pole, double throw
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Test Data Document
97942-128c099 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Manual Actuator Type And Quantity
1 toggle
-
Mounting Facility Type And Quantity
3 threaded bushing
-
Ultimate Trip Time Per Pole In Seconds
6.5000 minimum all locations and 30.000 maximum all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Arc Quenching Method
magnetic blowout
-
Bushing Length
0.375 inches nominal
-
Body Width
1.872 inches nominal
-
Frequency In Hertz
400.0 all locations
-
Thread Series Designator
unef
-
Terminal Type And Quantity
6 wire hook
-
Switch Current Rating And Type In Amps
1.0 ac and 0.5 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations