114-087
Relays and Solenoids
RELAY,ELECTROMAGNETIC
114-087
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Length
0.200 inches nominal
-
Overall Width
0.400 inches nominal
-
Environmental Protection
hermetic
-
Winding Quantity
1
-
Coil Quantity
1
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Mounting Facility Pattern
two position diagonal
-
Nonpile-Up Main Contact Arrangement
1 pole,double throw,one position momentary
-
Operating Voltage Rating And Type At Specified Temp
15.0 volts dc 25 deg celsius
-
Main Contact Maximum Voltage Rating In Volts
50.0 dc
-
Overall Length
1.180 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.000 inches nominal
-
Overall Height
1.490 inches nominal
-
Unthreaded Mounting Hole Diameter
0.096 inches nominal
-
Winding Dc Resistance Rating
2.5 kilohms nominal
-
Duty Type
continuous
-
Features Provided
polarized
-
Main Contact Load Current Rating At Maximum Rated Voltage
500.0 milliamperes dc
-
Terminal Type And Quantity
8 pin