M39019-1-59

Circuit Breakers

CIRCUIT BREAKER

M39019-1-59

5925-00-054-4102

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unef

  • Test Data Document

    81349-mil-c-39019 specification

  • Non-Definitive Government Spec/Std Reference

    milc39019-1

  • Manufacturers Code

    81349

  • Definitive Government Spec/Std Reference

    m39019-1-59

  • Frequency In Hertz

    400.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct and 0.950 maximum at 200 pct and 0.240 maximum at 400 pct single location

  • Nominal Thread Size

    0.375 inches

  • Actuator Position Designation

    at pole one

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay single location

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    1.700 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Body Length

    1.562 inches maximum

  • Terminal Type And Quantity

    2 wire hook

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Internal Trip Release Configuration

    series trip single location

  • Actuator Function

    trip-reset

  • Ultimate Trip Time Per Pole In Seconds

    0.200 minimum and 7.000 maximum single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Method

    magnetic single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Pole Quantity

    1

  • Case Material

    metal

  • Body Width

    0.625 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Body Style

    2a single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...