F3060

Circuit Breakers

CIRCUIT BREAKER

F3060

5925-00-055-6046

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    3.782 inches minimum and 3.906 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    7.063 inches minimum and 7.187 inches maximum

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac all locations

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.313 inches minimum and 1.437 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Unthreaded Mounting Hole Diameter

    0.281 inches nominal

  • Actuator Position Designation

    at pole two

  • Center To Center Distance Between Terminals Parallel To Width

    1.313 inches minimum and 1.437 inches maximum

  • Body Width

    4.063 inches minimum and 4.187 inches maximum

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Arc Quenching Method

    deion

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations

  • Body Length

    9.313 inches minimum and 9.437 inches maximum

  • Inclosure Protection Type For Which Designed

    general purpose

  • Boss Height

    0.438 inches minimum and 0.562 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    50.000 minimum at 200 pct all locations and 210.000 maximum at 200 pct all locations

  • Body Height

    3.751 inches minimum and 3.875 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...