ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Bushing Length
0.380 inches maximum
-
Inclosure Protection Type For Which Designed
vibrationproof and hermetically sealed
-
Maximum Continuous Load Current Rating Per Pole
100.0 milliamperes ac single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 ac single location
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location
-
Internal Trip Release Configuration
shunt trip single location
-
Thread Series Designator
unef
-
Mounting Surface To Terminal End Distance
1.605 inches maximum
-
Body Style
single pole type
-
Frequency In Hertz
50.0 single location or 60.0 single location
-
Arc Quenching Method
magnetic blowout
-
Unpackaged Unit Weight
2.200 ounces
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Trip Release Characteristic
time delay single location
-
Body Length
1.500 inches maximum
-
Manual Actuator Type And Quantity
1 toggle
-
Case Material
metal
-
Pole Quantity
1
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Circuit Protection Type
overcurrent single location
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.375 inches
-
Actuator Function
trip-reset
-
Storage Type
general purpose warehouse
-
Actuator Position Designation
at pole one
-
Reset Method
manual
-
Body Width
0.625 inches nominal
-
Special Handling Feature
magnetic
-
Terminal Type And Quantity
2 wire hook
-
Trip Release Method
magnetic single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.100 minimum at 200 pct single location and 0.600 maximum at 200 pct single location