Circuit Breakers

CIRCUIT BREAKER

DMS83059B

5925-00-055-9373

5925 - Circuit Breakers

Defense Electronics Supply Center

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Terminal Type And Quantity

    6 tab w/screw

  • Manual Actuator Type And Quantity

    3 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac all locations

  • Pole Quantity

    3

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Width

    2.263 inches minimum and 2.283 inches maximum

  • Mounting Surface To Terminal End Distance

    1.990 inches minimum and 2.010 inches maximum

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Bushing Length

    0.120 inches minimum and 0.140 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Frequency In Hertz

    60.0 all locations

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.802 inches minimum and 1.822 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.300 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations

  • Maximum Continuous Load Current Rating Per Pole

    7.0 amperes ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.180 inches minimum and 1.200 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...