CB5314

Circuit Breakers

CIRCUIT BREAKER

CB5314

5925-00-055-9374

5925 - Circuit Breakers

Edo

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations and 50.0 dc all locations

  • Body Width

    1.520 inches nominal

  • Mounting Surface To Terminal End Distance

    2.000 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.190 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.380 at 800 pct pascal all locations and 1.200 18 stage pascal all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Length

    2.500 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 nominal inches

  • Manual Actuator Type And Quantity

    2 toggle

  • Unpackaged Unit Weight

    4.250 ounces

  • Inclosure Protection Type For Which Designed

    dustproof and fungus resistant

  • External Actuator Linkage Arrangement

    one and two linked

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations and 3000.0 dc all locations

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac all locations and 2.5 amperes dc all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Terminal Type And Quantity

    4 screw

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...