CB5313
Circuit Breakers
CIRCUIT BREAKER
CB5313
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Protection Type For Which Designed
dustproof and fungus proof
-
Thread Series Designator
unc
-
Body Style
1c multipole-multiple actuator type
-
Bushing Length
0.146 inches minimum and 0.166 inches maximum
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Body Width
1.510 inches minimum and 1.530 inches maximum
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.802 inches minimum and 1.822 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Iii Fragility Factor
moderately rugged
-
Pole Quantity
2
-
Iii Arc Quenching Method
magnetic blowout
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Trip Release Characteristic
time delay all locations
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
2 toggle
-
Internal Trip Release Configuration
series trip all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.180 inches minimum and 1.200 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Mounting Surface To Terminal End Distance
1.990 inches minimum and 2.010 inches maximum
-
Mounting Facility Type And Quantity
4 threaded hole
-
Iii Storage Type
general purpose warehouse
-
Maximum Continuous Load Current Rating Per Pole
200.0 milliamperes ac all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
External Actuator Linkage Arrangement
one and two linked
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.300 minimum at 200 pct and 1.000 maximum at 200 pct all locations
-
Frequency In Hertz
50.0 or 60.0 all locations
-
Design Control Reference
2xam17-0-2-120-50-60-56
-
Manufacturers Code
74193
-
Terminal Type And Quantity
4 tab w/screw