31-079
Circuit Breakers
CIRCUIT BREAKER
31-079
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Width
1.250 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
875.0 ac and 875.0 dc
-
Circuit Protection Type
overcurrent
-
Trip Release Method
thermal
-
Trip Release Characteristic
time delay
-
Terminal Type And Quantity
2 screw
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac and 15.0 amperes dc
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac and 30.0 dc
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
7.000 minimum at 200 pct and 50.000 maximum at 200 pct and 0.060 minimum at 400 pct and 5.000 maximum at 400 pct and 0.000 minimum at 130 pct and 3600.000 maximum at 130 pct
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal
-
Thread Series Designator
unc
-
Overall Length
2.000 inches nominal
-
Overall Height
1.265 inches nominal
-
Case Material