116FTS259
Resistors
RESISTOR,VARIABLE,NONWIRE WOUND,PRECISION
116FTS259
RESISTOR,VARIABLE,NONWIRE WOUND,PRECISION
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Diameter
1.062 inches nominal
-
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation
156.36 8th section and 232.72 8th section
-
Pilot Diameter
0.9688 inches nominal
-
Fixed Tap Quantity Per Section
1 5th section
-
Pilot Diameter Runout
0.001 inches
-
Maximum Starting Torque
3.45 inch-ounces
-
Fixed Tap Quantity Per Section
1 7th section
-
Function Conformity Per Section
all sections absolute conformity
-
Shaft Radial Play
0.001 inches
-
Body Style
cylindrical servo mounted
-
Lateral Runout
0.001 inches
-
Function Conformity Tolerance Per Section
-1.50/+1.50 5th section
-
Body Length
2.680 inches nominal
-
Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
100.0 all sections
-
Function Conformity Tolerance Per Section
-1.50/+1.50 6th section
-
First Flat Length
0.375 inches nominal
-
Shaft Diameter
0.1247 inches nominal
-
Maximum Stop Torque
32.00 inch-ounces
-
Fixed Tap Quantity Per Section
3 2nd section
-
Pilot Length
0.6200 inches nominal
-
Mounting Lip Depth
0.0620 inches nominal
-
Fixed Tap Quantity Per Section
3 4th section
-
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation
156.36 7th section
-
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation
38.17 4th section and 87.27 4th section and 136.37 4th section
-
Shaft End Play
0.005 inches
-
Function Characteristic Per Section
all sections equation
-
Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius
-400.0/+400.0 all sections
-
Function Conformity Tolerance Per Section
-0.65/+0.65 10th section
-
Tap Location Tolerance Per Section
-2.0/+2.0 deg angular rotation all sections
-
Shaft Bearing Type
ball
-
Function Conformity Tolerance Per Section
-2.00/+2.00 9th section
-
Terminal Type And Quantity
45 turret
-
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation
156.36 5th section
-
Electrical Resistance Per Section
2.0 percent, rated amperes c select
-
Function Conformity Tolerance Per Section
-0.65/+0.65 3rd section
-
Function Conformity Tolerance Per Section
-0.30/+0.30 11th section
-
Flat Height
0.105 inches nominal
-
Effective Electrical Rotation In Deg Angular Rotation
340.0 nominal
-
Maximum Running Torque
3.45 inch-ounces
-
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation
156.36 6th section and 232.72 6th section
-
Function Conformity Tolerance Per Section
-1.50/+1.50 7th section
-
Function Conformity Tolerance Per Section
-1.50/+1.50 8th section
-
Function Conformity Tolerance Per Section
-0.25/+0.25 1st section
-
Rotary Actuator Travel In Angular Deg
360.0 nominal
-
Actuator Type
single shaft
-
Reliability Indicator
not established
-
Undercut Diameter
0.968 inches nominal
-
Electrical Resistance Per Section
20.0 percent, rated amperes c drop siding
-
Actuator Travel Control Feature
continuous motion
-
Shaft Style
round, flatted
-
Electrical Resistance Per Section
7.5 percent, rated amperes c and better industrial clears
-
Electrical Resistance Per Section
20.0 percent, rated amperes c finish
-
Mounting Method
clamp ring
-
Mounting Lip Diameter
1.0750 inches maximum
-
Resistance Tolerance Per Section In Percent
-10.0/+10.0 all sections
-
Electrical Resistance Per Section
30.0 percent, rated amperes c and better select
-
Electrical Resistance Per Section
20.0 percent, rated amperes c flooring
-
Function Conformity Tolerance Per Section
-1.00/+1.00 2nd section
-
Electrical Resistance Per Section
20.0 percent, rated amperes c industrial
-
Electrical Resistance Per Section
7.5 percent, rated amperes c and better v.g. stepping
-
Function Conformity Tolerance Per Section
-1.00/+1.00 4th section
-
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation
38.17 2nd section and 87.27 2nd section and 136.37 2nd section
-
Ambient Temp In Deg Celsius Per Section At Full Rated Power
25.0 all sections
-
Electrical Resistance Per Section
30.0 percent, rated amperes c ship decking
-
Power Dissipation Rating Per Section In Watts
1.0 free air all sections
-
Electrical Resistance Per Section
10.0 percent, rated amperes c and better finish
-
Electrical Resistance Per Section
30.0 percent, rated amperes foundation
-
Fixed Tap Quantity Per Section
2 6th section
-
Fixed Tap Quantity Per Section
2 8th section
-
Undercut Width
0.0570 inches minimum
-
Terminal Location
radially positioned over more than half the circumference
-
Shaft Length
0.437 inches nominal
-
Shaft Runout
0.002 inches
-
Test Data Document
97942-577r900 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Section Quantity
11