A091

Resistors

RESISTOR,VARIABLE,NONWIRE WOUND,PRECISION

A091

5905-00-056-4295

5905 - Resistors

Sensor Systems L.l.c.

RESISTOR,VARIABLE,NONWIRE WOUND,PRECISION

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Diameter

    1.062 inches nominal

  • Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation

    156.36 8th section and 232.72 8th section

  • Pilot Diameter

    0.9688 inches nominal

  • Fixed Tap Quantity Per Section

    1 5th section

  • Pilot Diameter Runout

    0.001 inches

  • Maximum Starting Torque

    3.45 inch-ounces

  • Fixed Tap Quantity Per Section

    1 7th section

  • Function Conformity Per Section

    all sections absolute conformity

  • Shaft Radial Play

    0.001 inches

  • Body Style

    cylindrical servo mounted

  • Lateral Runout

    0.001 inches

  • Function Conformity Tolerance Per Section

    -1.50/+1.50 5th section

  • Body Length

    2.680 inches nominal

  • Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power

    100.0 all sections

  • Function Conformity Tolerance Per Section

    -1.50/+1.50 6th section

  • First Flat Length

    0.375 inches nominal

  • Shaft Diameter

    0.1247 inches nominal

  • Maximum Stop Torque

    32.00 inch-ounces

  • Fixed Tap Quantity Per Section

    3 2nd section

  • Pilot Length

    0.6200 inches nominal

  • Mounting Lip Depth

    0.0620 inches nominal

  • Fixed Tap Quantity Per Section

    3 4th section

  • Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation

    156.36 7th section

  • Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation

    38.17 4th section and 87.27 4th section and 136.37 4th section

  • Shaft End Play

    0.005 inches

  • Function Characteristic Per Section

    all sections equation

  • Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius

    -400.0/+400.0 all sections

  • Function Conformity Tolerance Per Section

    -0.65/+0.65 10th section

  • Tap Location Tolerance Per Section

    -2.0/+2.0 deg angular rotation all sections

  • Shaft Bearing Type

    ball

  • Function Conformity Tolerance Per Section

    -2.00/+2.00 9th section

  • Terminal Type And Quantity

    45 turret

  • Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation

    156.36 5th section

  • Electrical Resistance Per Section

    2.0 percent, rated amperes c select

  • Function Conformity Tolerance Per Section

    -0.65/+0.65 3rd section

  • Function Conformity Tolerance Per Section

    -0.30/+0.30 11th section

  • Flat Height

    0.105 inches nominal

  • Effective Electrical Rotation In Deg Angular Rotation

    340.0 nominal

  • Maximum Running Torque

    3.45 inch-ounces

  • Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation

    156.36 6th section and 232.72 6th section

  • Function Conformity Tolerance Per Section

    -1.50/+1.50 7th section

  • Function Conformity Tolerance Per Section

    -1.50/+1.50 8th section

  • Function Conformity Tolerance Per Section

    -0.25/+0.25 1st section

  • Rotary Actuator Travel In Angular Deg

    360.0 nominal

  • Actuator Type

    single shaft

  • Reliability Indicator

    not established

  • Undercut Diameter

    0.968 inches nominal

  • Electrical Resistance Per Section

    20.0 percent, rated amperes c drop siding

  • Actuator Travel Control Feature

    continuous motion

  • Shaft Style

    round, flatted

  • Electrical Resistance Per Section

    7.5 percent, rated amperes c and better industrial clears

  • Electrical Resistance Per Section

    20.0 percent, rated amperes c finish

  • Mounting Method

    clamp ring

  • Mounting Lip Diameter

    1.0750 inches maximum

  • Resistance Tolerance Per Section In Percent

    -10.0/+10.0 all sections

  • Electrical Resistance Per Section

    30.0 percent, rated amperes c and better select

  • Electrical Resistance Per Section

    20.0 percent, rated amperes c flooring

  • Function Conformity Tolerance Per Section

    -1.00/+1.00 2nd section

  • Electrical Resistance Per Section

    20.0 percent, rated amperes c industrial

  • Electrical Resistance Per Section

    7.5 percent, rated amperes c and better v.g. stepping

  • Function Conformity Tolerance Per Section

    -1.00/+1.00 4th section

  • Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation

    38.17 2nd section and 87.27 2nd section and 136.37 2nd section

  • Ambient Temp In Deg Celsius Per Section At Full Rated Power

    25.0 all sections

  • Electrical Resistance Per Section

    30.0 percent, rated amperes c ship decking

  • Power Dissipation Rating Per Section In Watts

    1.0 free air all sections

  • Electrical Resistance Per Section

    10.0 percent, rated amperes c and better finish

  • Electrical Resistance Per Section

    30.0 percent, rated amperes foundation

  • Fixed Tap Quantity Per Section

    2 6th section

  • Fixed Tap Quantity Per Section

    2 8th section

  • Undercut Width

    0.0570 inches minimum

  • Terminal Location

    radially positioned over more than half the circumference

  • Shaft Length

    0.437 inches nominal

  • Shaft Runout

    0.002 inches

  • Test Data Document

    97942-577r900 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Section Quantity

    11

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...