7013-01

Switches

SWITCH,PRESSURE

7013-01

5930-00-058-1576

5930 - Switches

Bendix Commercial Vehicle Systems

SWITCH,PRESSURE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-s-12211 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performanc

  • Outside Diameter

    0.250 inches nominal single connection

  • Mounting Method

    bracket and unthreaded hole

  • Thread Series Designator

    npt single pressure connection

  • Contact Load Current Rating

    5.0 amperes resistive load single voltage and 3.0 amperes inductive load single voltage and 3.0 amperes lamp load single voltage

  • Specification/Standard Data

    96906-ms27152 government standard

  • Features Provided

    hermetically sealed case

  • Contact Stimulus Rating

    60.00 actuation point nominal pounds per square inch gage and 66.00 deactuation point nominal pounds per square inch and 6.00 differential point nominal pounds per square inch

  • Style Designator

    cylindrical w/bracket

  • Overall Length

    4.188 inches maximum

  • Thread Quantity Per Inch

    18 single pressure connection

  • Contact Voltage Rating In Volts

    24.0 dc at sea level single voltage

  • Pressure Connector Type

    plain, threaded external single connection

  • Overall Height

    2.140 inches maximum

  • Pressure Switch Type

    gage

  • Contact Action Stimulus

    decrease

  • Terminal Type

    connector, plug

  • Nominal Thread Size

    0.250 inches single pressure connection

  • Contact Adjustability

    deactuation point not adjustable and actuation point not adjustable

  • Mounting Facility Pattern

    two position in-line

  • Body Diameter

    1.875 inches nominal

  • Hazardous Locations/Environmental Protection

    weatherproof

  • Distance Between Mounting Facility Centers

    1.250 inches nominal

  • Media For Which Designed

    gas

  • Unthreaded Mounting Hole Diameter

    0.281 inches nominal

  • Nonpile-Up Contact Arrangement

    1 pole, single throw, normally open, momentary action

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...