A0B230

Circuit Breakers

CIRCUIT BREAKER

A0B230

5925-00-062-3743

5925 - Circuit Breakers

Schneider Electric Usa Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Body Width

    1.484 inches nominal

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Terminal Type And Quantity

    4 screw

  • Body Height

    2.922 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    2.469 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.938 inches nominal

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac first location and 240.0 dc first location

  • Boss Height

    0.156 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    167.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.469 inches nominal

  • Body Length

    2.563 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    120.000 nominal at 200 pct all locations

  • Center To Center Distance Between Terminals Parallel To Length

    2.938 inches nominal

  • External Actuator Linkage Arrangement

    one and two linked

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...