4170600-26

Relays and Solenoids

RELAY,ELECTROMAGNETIC

4170600-26

5945-00-062-8279

5945 - Relays and Solenoids

Raytheon Company

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Mounting Facility Type And Quantity

    4 unthreaded hole single mounting facility

  • Mounting Facility Pattern

    rectangular single mounting facility

  • Storage Type

    general purpose warehouse

  • Overall Length

    3.700 inches maximum

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    2.687 inches nominal single mounting facility

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    5.0 amperes ac resistive load and 5.0 amperes dc resistive load

  • Operating Voltage Rating And Type At Specified Temp

    115.0 volts ac 25 deg celsius single winding

  • Environmental Protection

    hermetic

  • Auxiliary Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Overall Height

    4.485 inches nominal

  • Arc Quenching Method

    air

  • Overall Width

    3.305 inches maximum

  • Winding Quantity

    1

  • Time Delay

    0.065 seconds maximum fixed release time

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    750.0 milliamperes ac lamp load and 750.0 milliamperes dc lamp load

  • Main Contact Load Current Rating At Maximum Rated Voltage

    50.0 amperes ac resistive load and 50.0 amperes dc resistive load

  • Case Material

    metal

  • Frequency In Hertz

    400.0 nominal

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    5.0 amperes ac inductive load and 5.0 amperes dc inductive load

  • Unthreaded Mounting Hole Diameter

    0.218 inches nominal single mounting facility

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Nonpile-Up Auxiliary Contact Arrangement

    1 pole, single throw, normally closed, double break, momentary action and 1 pole, single throw, normally open, double make, momentary action

  • Cubic Measure

    39.131 cubic inches

  • Main Contact Load Current Rating At Maximum Rated Voltage

    50.0 amperes ac inductive load and 50.0 amperes dc inductive load

  • Terminal Type And Quantity

    12 threaded stud all functions

  • Time Delay

    0.03 seconds maximum fixed operate time

  • Test Data Document

    81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Purpose For Which Designed

    general

  • Coil Quantity

    1

  • Main Contact Load Current Rating At Maximum Rated Voltage

    50.0 amperes ac motor load and 50.0 amperes dc motor load

  • Specification/Standard Data

    96906-ms24376 government standard

  • Duty Type

    continuous

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    3.250 inches nominal single mounting facility

  • Nonpile-Up Main Contact Arrangement

    3 pole, single throw, normally open, double make, momentary action

  • ~1

    data on certain environmental and performance

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...