6042H50
Relays and Solenoids
RELAY,ELECTROMAGNETIC
6042H50
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Mounting Facility Type And Quantity
4 unthreaded hole single mounting facility
-
Mounting Facility Pattern
rectangular single mounting facility
-
Storage Type
general purpose warehouse
-
Overall Length
3.700 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.687 inches nominal single mounting facility
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac resistive load and 5.0 amperes dc resistive load
-
Operating Voltage Rating And Type At Specified Temp
115.0 volts ac 25 deg celsius single winding
-
Environmental Protection
hermetic
-
Auxiliary Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Overall Height
4.485 inches nominal
-
Arc Quenching Method
air
-
Overall Width
3.305 inches maximum
-
Winding Quantity
1
-
Time Delay
0.065 seconds maximum fixed release time
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
750.0 milliamperes ac lamp load and 750.0 milliamperes dc lamp load
-
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac resistive load and 50.0 amperes dc resistive load
-
Case Material
metal
-
Frequency In Hertz
400.0 nominal
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac inductive load and 5.0 amperes dc inductive load
-
Unthreaded Mounting Hole Diameter
0.218 inches nominal single mounting facility
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Nonpile-Up Auxiliary Contact Arrangement
1 pole, single throw, normally closed, double break, momentary action and 1 pole, single throw, normally open, double make, momentary action
-
Cubic Measure
39.131 cubic inches
-
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac inductive load and 50.0 amperes dc inductive load
-
Terminal Type And Quantity
12 threaded stud all functions
-
Time Delay
0.03 seconds maximum fixed operate time
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Purpose For Which Designed
general
-
Coil Quantity
1
-
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac motor load and 50.0 amperes dc motor load
-
Specification/Standard Data
96906-ms24376 government standard
-
Duty Type
continuous
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.250 inches nominal single mounting facility
-
Nonpile-Up Main Contact Arrangement
3 pole, single throw, normally open, double make, momentary action
-
~1
data on certain environmental and performance