501I301
Circuit Breakers
CIRCUIT BREAKER
501I301
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Trip Release Method
magnetic single location
-
Terminal Type And Quantity
2 wire hook
-
Special Handling Feature
magnetic
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Length
0.687 inches nominal
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Ultimate Trip Time Per Pole In Seconds
0.035 nominal single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Pole Quantity
1
-
Case Material
metal
-
Mounting Surface To Terminal End Distance
1.500 inches nominal
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
-
Main Contact Tripping Mechanism Type
trip free
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Inclosure Protection Type For Which Designed
vibrationproof and shockproof and hermetically sealed
-
Body Style
single pole type
-
Body Width
0.625 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Thread Series Designator
unef
-
Maximum Continuous Load Current Rating Per Pole
300.0 milliamperes dc single location
-
Body Length
1.750 inches maximum
-
Trip Release Characteristic
instantaneous single location
-
Bushing Length
0.305 inches maximum