FAE34100NS

Circuit Breakers

CIRCUIT BREAKER

FAE34100NS

5925-00-064-3031

5925 - Circuit Breakers

Square D Co

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Body Style

    rectangular dimensional envelope

  • Actuator Function

    trip w/separate reset

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations and 100.0 amperes dc all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 300 pct all locations and 60.000 maximum at 300 pct all locations

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Trip Release Method

    thermal all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 250.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    7500.0 ac all locations and 5000.0 dc all locations

  • Overall Length

    13.750 inches nominal

  • Terminal Type And Quantity

    6 screw

  • Overall Height

    4.125 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Case Material

    metal

  • Test Data Document

    36378-65375 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Actuator Position Designation

    at pole two

  • Overall Width

    8.500 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...