A2028633
Circuit Breakers
CIRCUIT BREAKER
A2028633
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
single location and 3.500 maximum at 300 pct sing
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 maximum at 500 pct single location and 1.200 minimum at 300 pct single location and 9.000 maximum at 200 pct single location and 7.000 minimum at 150 pct single location and 0.300 minimum at 500 pct single location and 0.010 minimum at 1000 pct
-
Trip Release Method
magnetic single location
-
Inclosure Protection Type For Which Designed
dustproof
-
Reset Method
manual
-
Overall Length
2.500 inches nominal
-
Mounting Facility Type And Quantity
2 threaded hole
-
Overall Width
0.750 inches nominal
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Overall Height
3.170 inches nominal
-
Pole Quantity
1
-
Manual Actuator Type And Quantity
1 toggle
-
Nominal Thread Size
0.138 inches
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location
-
Frequency In Hertz
60.0 single location
-
Trip Release Characteristic
instantaneous single location and time delay single location
-
Trip Release Duty Cycle
continuous single location
-
Case Material
plastic
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac single location
-
Terminal Type And Quantity
2 threaded stud
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Special Features
mtg holes on 2 1/16 in. centers
-
Maximum Continuous Load Current Rating Per Pole
6.0 amperes ac single location