CP35-5-70-10A4P

Circuit Breakers

CIRCUIT BREAKER

CP35-5-70-10A4P

5925-00-068-9540

5925 - Circuit Breakers

Lockheed Martin Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    12a single pole type

  • Body Width

    0.750 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.140 inches nominal

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Terminal Type And Quantity

    2 threaded stud

  • Body Length

    2.500 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct single location and 0.500 maximum at 200 pct

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...