TFJ236150WLTFKUVA1RSTFKASA6AB1LS

Circuit Breakers

CIRCUIT BREAKER

TFJ236150WLTFKUVA1RSTFKASA6AB1LS

5925-00-069-2005

5925 - Circuit Breakers

General Electric Co

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    4.125 inches nominal

  • Reset Method

    manual

  • Unthreaded Mounting Hole Diameter

    0.196 inches nominal

  • Switch Location And Position Designation

    internal at pole three

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Switch Terminal Type

    wire lead

  • Center To Center Distance Between Terminals Parallel To Length

    7.750 inches nominal

  • Body Length

    10.125 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    90.000 minimum at 200 pct all locations and 300.000 maximum at 200 pct all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Body Height

    3.188 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    7.750 inches nominal

  • Switch Voltage Rating And Type In Volts

    600.0 ac and 240.0 dc

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Current Rating And Type In Amps

    6.0 ac and 0.25 dc

  • Body Style

    multipole-single actuator type

  • Boss Height

    0.250 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...