52-B-1074-3

Circuit Breakers

CIRCUIT BREAKER

52-B-1074-3

5925-00-069-7142

5925 - Circuit Breakers

Engineered Arresting Systems

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Delay Time In Seconds Per Rated Continuous Current

    6.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1.000 ac single location and 1.000 dc single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Inclosure Protection Type For Which Designed

    shockproof and salt spray proof and humidity proof and vibrationproof

  • Body Style

    single pole type

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac single location and 35.0 amperes dc single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Unpackaged Unit Weight

    0.125 pounds

  • Nominal Thread Size

    0.469 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 50.0 dc single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.020 inches nominal

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Body Length

    1.375 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Mounting Surface To Terminal End Distance

    2.035 inches nominal

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Body Width

    0.690 inches nominal

  • Bushing Length

    0.335 inches nominal

  • Trip Release Characteristic

    time delay single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...