AM0666MG6-25-208VAC60C4

Circuit Breakers

CIRCUIT BREAKER

AM0666MG6-25-208VAC60C4

5925-00-071-9844

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent second location

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac second location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Body Style

    multipole-multiple actuator type

  • Circuit Protection Type

    overcurrent third location

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac third location

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Body Width

    2.960 inches minimum and 3.040 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 fourth location

  • Trip Release Characteristic

    time delay fourth location

  • Terminal Type And Quantity

    8 threaded stud

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.100 minimum at 200 pct second location and 14.000 maximum at 200 pct second location

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Frequency In Hertz

    60.0 all locations

  • Trip Release Characteristic

    time delay second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 second location

  • Inclosure Protection Type For Which Designed

    moisture resistant and fungus resistant and shock resistant and humidity resistant and vibration resistant

  • Internal Trip Release Configuration

    relay trip fourth location

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac second location

  • Internal Trip Release Configuration

    relay trip second location

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Trip Release Method

    magnetic-hydraulic fourth location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Trip Release Method

    magnetic-hydraulic second location

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac fourth location

  • Trip Release Method

    magnetic-hydraulic third location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Manual Actuator Type And Quantity

    4 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Case Material

    plastic

  • Mounting Surface To Terminal End Distance

    2.539 inches minimum and 2.683 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac fourth location

  • Pole Quantity

    4

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Internal Trip Release Configuration

    relay trip third location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Unpackaged Unit Weight

    13.000 ounces

  • Circuit Protection Type

    overcurrent fourth location

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac fourth location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.100 minimum at 200 pct fourth location and 14.000 maximum at 200 pct fourth location

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac third location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.100 minimum at 200 pct third location and 14.000 maximum at 200 pct third location

  • Arc Quenching Method

    magnetic blowout

  • Trip Release Characteristic

    time delay third location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 third location

  • Special Features

    pole one is switch only

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...