Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    1.158 inches minimum and 1.218 inches maximum

  • Trip Release Method

    thermal single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Pole Quantity

    1

  • Unpackaged Unit Weight

    0.158 pounds

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location and 15.0 amperes dc single location

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.807 inches minimum and 1.817 inches maximum

  • Bushing Length

    0.250 inches maximum

  • Body Width

    0.750 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 5000.0 dc single location

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Mounting Facility Type And Quantity

    1 threaded hole

  • Body Length

    2.188 inches maximum

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Circuit Protection Type

    overcurrent single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...