PS2-2457-5

Circuit Breakers

CIRCUIT BREAKER

PS2-2457-5

5925-00-075-7892

5925 - Circuit Breakers

Lockheed Martin Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.500 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Mounting Surface To Terminal End Distance

    1.359 inches nominal

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    75.000 nominal at 100 pct and 10.000 minimum at 125 pct and 75.000 maximum at 125 pct and 5.000 minimum at 200 pct and 9.000 maximum at 200 pct and 0.700 minimum at 400 pct and 2.000 maximum at 400 pct and 0.500 minimum at 500 pct and 1.000 maximum at

  • Inclosure Protection Type For Which Designed

    explosion proof and fungus resistant and moisture resistant

  • Frequency In Hertz

    60.0 single location

  • Manufacturers Code

    06887

  • Body Style

    12a single pole type

  • Body Width

    0.750 inches nominal

  • Boss Height

    0.125 inches nominal

  • Pole Quantity

    1

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Ultimate Trip Time Per Pole In Seconds

    10.000 minimum and 75.000 maximum single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    between pole one and two

  • Nominal Thread Size

    0.190 inches

  • ~1

    500 pct single location

  • Design Control Reference

    ps2-2457-5

  • Thread Series Designator

    unf

  • Terminal Type And Quantity

    2 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...