AM13MG3-10-A-250-4-60

Circuit Breakers

CIRCUIT BREAKER

AM13MG3-10-A-250-4-60

5925-00-079-5680

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Body Width

    0.760 inches maximum

  • Body Length

    2.530 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct single location and 10.000 maximum at 200 pct single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.800 inches minimum and 1.820 inches maximum

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Thread Series Designator

    unc

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches maximum

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.690 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Precious Material And Location

    contact surfaces silver

  • Body Style

    single pole type

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Unpackaged Unit Weight

    4.250 ounces

  • Frequency In Hertz

    60.0 single location

  • Inclosure Protection Type For Which Designed

    explosion proof and shock resistant and vibrationproof and fungus resistant and moisture resistant

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...