Technical Characteristics
-
Mounting Method
threaded bushing single group
-
Winding Tap Location (Non-Core)
center tap single component single winding
-
Thread Series Designator
un single group
-
Body Length
1.560 inches maximum
-
Thread Class (Non-Core)
2a single group
-
Thread Quantity Per Inch
32 single group
-
Terminal Type And Quantity
3 tab, solder lug
-
Thread Direction (Non-Core)
right-hand single group
-
Overall Length
2.560 inches maximum
-
Winding Quantity
1 single component
-
Reliability Indicator
not established
-
Rating Method
electrical single component single winding
-
Inductance Rating
500.00 millihenries nominal single component single winding
-
Inclosure Type
hermetically sealed
-
Inductance Type
fixed
-
Nominal Thread Size
0.500 inches single group
-
Body Outside Diameter
1.500 inches nominal
-
Winding Operating Current
25.0 milliamperes maximum of standard range b and better drop siding single component single winding
-
Dc Resistance Rating In Ohms
600.000 single component single winding