SM3-0-25-230-400-58

Circuit Breakers

CIRCUIT BREAKER

SM3-0-25-230-400-58

5925-00-079-6662

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    0.870 inches minimum and 0.880 inches maximum

  • Fragility Factor

    moderately rugged

  • Terminal Type And Quantity

    2 wire hook

  • Mounting Surface To Terminal End Distance

    1.524 inches minimum and 1.586 inches maximum

  • Body Width

    0.567 inches minimum and 0.629 inches maximum

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.375 inches

  • Maximum Continuous Load Current Rating Per Pole

    250.0 milliamperes ac single location

  • Thread Quantity Per Inch

    32

  • Body Length

    1.448 inches minimum and 1.510 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Bushing Length

    0.360 inches minimum and 0.380 inches maximum

  • Pole Quantity

    1

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and explosion resistant and hermetically sealed

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Thread Series Designator

    unef

  • Ultimate Trip Time Per Pole In Seconds

    0.800 minimum single location and 3.000 maximum single location

  • Operating Voltage Type And Rating Per Pole In Volts

    230.0 ac single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.040 minimum at 300 pct single location and 0.400 minimum at 150 pct single location and 2.000 maximum at 150 pct single location and 0.600 maximum at 200 pct single location and 0.150 minimum at 200 pct single location and 0.200 maximum at 300 pct

  • ~1

    single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...