524179

Circuit Breakers

CIRCUIT BREAKER

524179

5925-00-080-1019

5925 - Circuit Breakers

International Business Machines Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 push button

  • Terminal Type And Quantity

    2 screw

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Ambient Temp Rating

    24.0 deg celsius nominal single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    23.000 minimum at 200 pct single location and 23.000 maximum at 300 pct single location

  • Inclosure Protection Type For Which Designed

    dustproof and fungus resistant

  • Switch Location And Position Designation

    internal at pole one

  • Auxiliary Switch Function And Quantity

    1 control

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    230.0 ac single location and 20.0 dc single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    200.0 ac single location and 200.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    8.0 amperes ac single location and 8.0 amperes dc single location

  • Boss Height

    0.120 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.000 inches nominal

  • Switch Voltage Rating And Type In Volts

    115.0 ac and 50.0 dc

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Surface To Terminal End Distance

    1.910 inches nominal

  • Overall Width

    0.997 inches maximum

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    1.656 inches nominal

  • Switch Terminal Type

    pin

  • Frequency In Hertz

    60.0 single location

  • Overall Length

    1.969 inches nominal

  • Switch Current Rating And Type In Amps

    3.0 ac and 3.0 dc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...