CCPBA11

Circuit Breakers

CIRCUIT BREAKER

CCPBA11

5925-00-080-2036

5925 - Circuit Breakers

Telemecanique Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 300.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    200.0 ac single location and 200.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    23.000 nominal at 200 pct single location and 4.400 nominal at 300 pct

  • Body Style

    16a single pole type

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location and 1.0 amperes dc

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 push button

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Switch Terminal Type

    pin

  • Frequency In Hertz

    400.0 single location

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 screw

  • Body Length

    2.000 inches nominal

  • Body Width

    1.312 inches nominal

  • Body Height

    1.938 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.625 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...