HF3050
Circuit Breakers
CIRCUIT BREAKER
HF3050
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations
-
Reset Method
manual
-
Trip Release Characteristic
time delay all locations
-
Internal Trip Release Configuration
series trip all locations
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Unthreaded Mounting Hole Diameter
0.281 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
20000.0 ac all locations
-
Frequency In Hertz
60.0 all locations
-
Terminal Type And Quantity
6 compression
-
Main Contact Tripping Mechanism Type
trip free
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Trip Delay Time In Seconds Per Rated Continuous Current
50.000 minimum at 200 pct all locations and 208.000 maximum at 200 pct all locations
-
Ultimate Trip Time Per Pole In Seconds
400.000 minimum all locations and 1000.000 maximum all locations
-
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
-
Case Material
plastic