SM3-0-5-50DC59

Circuit Breakers

CIRCUIT BREAKER

SM3-0-5-50DC59

5925-00-081-1632

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.375 inches

  • Thread Series Designator

    unef

  • Body Length

    1.448 inches minimum and 1.510 inches maximum

  • Body Width

    0.567 inches minimum and 0.629 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.870 inches minimum and 0.880 inches maximum

  • Mounting Surface To Terminal End Distance

    1.524 inches minimum and 1.586 inches maximum

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Time Per Pole In Seconds

    0.600 minimum and 5.000 maximum single location

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • ~1

    ct and 1.000 maximum at 200 pct and 0.020 minimum at 300 pct and 0.400 maximum a

  • ~2

    t 300 pct single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.300 minimum at 150 pct and 2.500 maximum at 150 pct and 0.100 minimum at 200 p

  • Inclosure Protection Type For Which Designed

    explosion resistant and fungus resistant and hermetically sealed

  • Terminal Type And Quantity

    2 wire hook

  • Body Style

    2a single pole type

  • Bushing Length

    0.360 inches minimum and 0.380 inches maximum

  • Case Material

    metal

  • Fragility Factor

    moderately rugged

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Circuit Protection Type

    overcurrent single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...