2MC1-202-20
Circuit Breakers
CIRCUIT BREAKER
2MC1-202-20
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 minimum at 200 pct single location and 10.300 maximum at 200 pct single location
-
Nominal Thread Size
0.469 inches
-
Operating Voltage Type And Rating Per Pole In Volts
220.0 ac single location
-
Case Material
plastic
-
Ultimate Trip Time Per Pole In Seconds
3.000 minimum single location and 10.500 maximum single location
-
Trip Release Method
magnetic single location
-
Body Width
0.625 inches nominal
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Mounting Surface To Terminal End Distance
1.638 inches nominal
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Bushing Length
0.290 inches nominal
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Body Length
1.750 inches nominal
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Pole Quantity
1
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
800.0 ac single location
-
Frequency In Hertz
400.0 single location
-
Center To Center Distance Between Terminals Parallel To Length
0.255 inches nominal
-
Body Style
single pole type
-
Terminal Type And Quantity
2 tab w/screw
-
Unpackaged Unit Weight
2.000 ounces