900060-0009
Resistors
RESISTOR,THERMAL
900060-0009
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Temp Points For Resistance Readings At Zero Power
90.0 deg celsius 6th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
300.0 deg celsius 10th resistance-temperature point
-
Ambient Temp At Full Rated Power
25.0 deg celsius
-
Zero Power Resistance At Specified Temp
826.5 ohms 4th resistance-temperature point
-
Zero Power Resistance At Specified Temp
12.5 ohms 9th resistance-temperature point
-
Zero Power Resistance At Specified Temp
29.4 ohms 8th resistance-temperature point
-
Body Outside Diameter
0.050 inches maximum
-
Temp Points For Resistance Readings At Zero Power
120.0 deg celsius 7th resistance-temperature point
-
Zero Power Resistance At Specified Temp
12.6 kilohms 2nd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-23.3/+23.3 5th resistance-temperature point
-
Zero Power Resistance At Specified Temp
291.5 ohms 5th resistance-temperature point
-
Zero Power Resistance At Specified Temp
120.5 ohms 6th resistance-temperature point
-
Zero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius
-3.90
-
Resistance Tolerance At A Specified Temp In Percent
-22.5/+22.5 3rd resistance-temperature point
-
Zero Power Resistance At Specified Temp
76.1 kilohms 1st resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-20.5/+20.5 4th resistance-temperature point
-
Zero Power Resistance At Specified Temp
56.6 ohms 7th resistance-temperature point
-
Body Length
0.080 inches maximum
-
Zero Power Resistance
1.000 kilohms
-
Temp Points For Resistance Readings At Zero Power
60.0 deg celsius 5th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-27.5/+27.5 7th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-26.3/+26.3 2nd resistance-temperature point
-
Zero Power Resistance At Specified Temp
2.8 kilohms 3rd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-29.2/+29.2 8th resistance-temperature point
-
Terminal Length
1.000 inches minimum
-
Temp Points For Resistance Readings At Zero Power
150.0 deg celsius 8th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
30.0 deg celsius 4th resistance-temperature point
-
Terminal Diameter
0.004 inches nominal
-
Maximum Operating Temp
300.0 deg celsius
-
Resistance Tolerance At A Specified Temp In Percent
-30.9/+30.9 1st resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
0.0 deg celsius 3rd resistance-temperature point
-
Zero Power Resistance At Specified Temp
3.8 ohms 10th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-30.0 deg celsius 2nd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-60.0 deg celsius 1st resistance-temperature point
-
Terminal Type And Quantity
2 wire lead
-
Reliability Indicator
not established
-
Style Designator
sealed or coated bead
-
Zero Power Resistance Tolerance In Percent At Reference Temp
-20.0/+20.0
-
Resistance Tolerance At A Specified Temp In Percent
-34.5/+34.5 10th resistance-temperature point
-
Inclosure Type
encapsulated
-
Temp Points For Resistance Readings At Zero Power
200.0 deg celsius 9th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-25.6/+25.6 6th resistance-temperature point
-
Power Dissipation Constant In Milliwatts Per Deg Celsius
0.4
-
Thermal Time Constant In Seconds
4.0
-
Resistance Tolerance At A Specified Temp In Percent
-31.4/+31.4 9th resistance-temperature point