260-3061-000

Circuit Breakers

CIRCUIT BREAKER

260-3061-000

5925-00-083-8480

5925 - Circuit Breakers

Rockwell Collins Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Bushing Length

    0.250 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 single location

  • Thread Series Designator

    unc

  • Center To Center Distance Between Terminals Parallel To Length

    0.812 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Maximum Continuous Load Current Rating Per Pole

    750.0 milliamperes ac single location

  • Manual Actuator Type And Quantity

    1 push button

  • Terminal Type And Quantity

    2 screw

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location

  • Body Length

    1.094 inches maximum

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    0.797 inches nominal

  • Inclosure Protection Type For Which Designed

    explosion resistant and moisture resistant

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    60.000 minimum at 200 pct single location and 15.000 maximum at 300 pct single location

  • Body Width

    0.750 inches maximum

  • Nominal Thread Size

    0.469 inches

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...