337-458-9001
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
337-458-9001
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Body Surface Treatment
tin
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Unthreaded Mounting Hole Diameter
0.150 inches maximum
-
Operating Current Rating Per Function In Amps
0.3 1st radio interference
-
Maximum Dielectric Withstanding Dc Voltage
200.0 volts at sea level
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Maximum Voltage Drop Per Function
150.0 millivolts dc 1st radio interference
-
Operating Current Rating Per Function In Amps
0.3 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Vibration Resistance Range In Hertz
+10.0/+55.0
-
Operating Temp Range
-65.0/+85.0 deg celsius
-
Maximum Voltage Drop Per Function
150.0 millivolts dc 2nd radio interference
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Maximum Temp Rise
25.0 deg celsius
-
Operating Voltage Rating And Type Per Function
26.0 volts ac 2nd radio interference 2nd function and 28.0 volts dc 2nd radio interference 2nd function
-
Body Width
1.060 inches maximum
-
Inclosure Type
encased
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.452 inches maximum
-
Functional Terminal Type And Quantity
2 tab, solder lug input 1st function
-
Body Length
1.180 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Overall Height
0.780 inches maximum
-
Overall Width
1.380 inches maximum
-
Operating Voltage Rating And Type Per Function
26.0 volts ac 1st radio interference 1st function and 28.0 volts dc 1st radio interference 1st function
-
Overall Length
1.750 inches maximum
-
Functional Terminal Type And Quantity
2 tab, solder lug output 2nd function
-
Test Data Document
70210-337-458-9001 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference