G4099
Circuit Breakers
CIRCUIT BREAKER
G4099
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
50000.0 dc all locations
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Unthreaded Mounting Hole Diameter
0.196 inches nominal
-
Center To Center Distance Between Terminals Parallel To Width
1.500 inches nominal
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 minimum at 200 pct all locations and 400.000 maximum at 200 pct all locations
-
Case Material
plastic
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 all locations
-
Internal Trip Release Configuration
series trip all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.359 inches nominal
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Body Width
3.000 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
6.250 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
55.0 amperes dc all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Body Length
7.000 inches nominal
-
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc all locations
-
Boss Height
0.219 inches nominal
-
Manual Actuator Type And Quantity
2 toggle
-
Mounting Surface To Terminal End Distance
2.688 inches nominal
-
Terminal Type And Quantity
4 threaded stud
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.500 inches nominal
-
External Actuator Linkage Arrangement
one and two linked