AX-96878
Coils and Transformers
COIL,RADIO FREQUENCY
AX-96878
COIL,RADIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Adjustment Method And Quantity
1 adjustable core single component
-
(Non-Core Data) Frequency At Which Inductance And Quality Factor Applies
51.0 megahertz single component single winding
-
Inclosure Type
open
-
Body Length
0.804 inches nominal
-
Turn Quantity
15-1/2 single component single winding
-
Reliability Indicator
not established
-
Terminal Type And Quantity
2 wire lead
-
Quality Factor
65 minimum single component single winding
-
Winding Conductor Size
0.01594 inches american wire gage single component single winding
-
Rating Method
electrical and winding turns single component single winding
-
Mounting Method
terminal single group
-
Iii Maximum Operating Temp
65.0 deg celsius
-
Overall Diameter
0.214 inches minimum and 0.218 inches maximum
-
Adjustment Device Drive Type
shaft single component
-
Core Construction
powdered single component
-
Coil Form Type
hollow single component
-
Inductance Rating
0.95 microhenries minimum and 2.00 microhenries maximum single component single winding