711525-36

Circuit Breakers

CIRCUIT BREAKER

711525-36

5925-00-097-7490

5925 - Circuit Breakers

Raytheon Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    4200.0 ac all locations and 4200.0 dc all locations

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Switch Current Rating And Type In Amps

    7.0 dc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Bushing Length

    0.235 inches minimum and 0.250 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 all locations

  • Switch Terminal Type

    wire lead

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations and 20.0 amperes dc all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole two

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.800 inches minimum and 1.820 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Body Style

    multipole-single actuator type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct all locations and 50.000 maximum at 200 pct all locations

  • Body Height

    2.460 inches minimum and 2.480 inches maximum

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    2.189 inches maximum

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Switch Location And Position Designation

    internal at pole three

  • Storage Type

    general purpose warehouse

  • Body Length

    2.250 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Center To Center Distance Between Terminals Parallel To Length

    1.180 inches minimum and 1.200 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    205.0 ac all locations and 50.0 dc all locations

  • Terminal Type And Quantity

    6 tab w/screw

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...