Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.235 inches minimum single mounting facility single center group and 0.265 inches maximum single mounting facility single center group
-
Inductance Rating
0.44 microhenries nominal single component single secondary
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Maximum Operating Temp
105.0 deg celsius
-
Overall Length
0.490 inches minimum and 0.510 inches maximum
-
Terminal Type And Quantity
5 wire lead
-
Overall Width
0.365 inches minimum and 0.385 inches maximum
-
Frequency Rating
1.265 megahertz nominal single component
-
Reliability Indicator
not established
-
Coil Form Type
solid single component
-
Mounting Method
terminal single group
-
Rating Method
electrical single component single secondary
-
Overall Height
0.365 inches minimum and 0.385 inches maximum
-
Winding Tap Location (Non-Core)
center tap single component single secondary
-
Cubic Measure (Non-Core)
0.08 cubic inches
-
Center To Center Distance Between Mounting Facilities Parallel To Length
0.285 inches minimum single mounting facility single center group and 0.315 inches maximum single mounting facility single center group
-
Features Provided
tinned wire leads