87612
Switches
SWITCH,PRESSURE
87612
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Diameter
2.950 inches maximum
-
Media For Which Designed
liquid
-
Pressure Connector Type
swivel nut, inverted flare, threaded external single connection
-
Contact Load Current Rating
15.0 amperes resistive load single voltage
-
Terminal Type
quick disconnect, male
-
Mounting Method
base and slot
-
Style Designator
cylindrical w/bracket
-
Distance Between Mounting Facility Centers
1.700 inches minimum and 1.750 inches maximum
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Contact Stimulus Rating
5.30 deactuation point nominal inches of water and 8.60 actuation point nominal inches of water and 3.60 differential point nominal inches of water
-
Mounting Slot Width
0.260 inches nominal
-
Contact Voltage Rating In Volts
125.0 ac at sea level single voltage
-
Overall Height
5.362 inches nominal
-
Pressure Switch Type
gage
-
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable
-
Mounting Facility Pattern
two position in-line
-
Contact Action Stimulus
increase