GJ1-B3-DU0150-03C

Circuit Breakers

CIRCUIT BREAKER

GJ1-B3-DU0150-03C

5925-00-100-5242

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Thread Series Designator

    unc

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Body Length

    3.719 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes dc single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct single location and 0.500 maximum at 200 pct single location

  • Body Width

    0.990 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    3.063 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    3.177 inches minimum and 3.301 inches maximum

  • Unpackaged Unit Weight

    0.690 pounds

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Boss Height

    0.156 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...