61310-10
Circuit Breakers
CIRCUIT BREAKER
61310-10
Instruments And Flight Research Inc.
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
12a single pole type
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Switch Contact Arrangement
single pole, single throw, normally closed
-
Iii Fragility Factor
moderately rugged
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
2 threaded hole
-
Iii Special Handling Feature
magnetic
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location
-
Trip Release Method
magnetic single location
-
Trip Release Characteristic
time delay single location
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
Thread Series Designator
unc
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
at pole one
-
Auxiliary Switch Function And Quantity
1 alarm
-
Switch Location And Position Designation
external at pole one
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.300 minimum at 200 pct and 6.500 maximum at 200 pct single location
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant and explosion resistant
-
Switch Terminal Type
tab, solder lug
-
Switch Current Rating And Type In Amps
10.0 ac and 2.5 dc
-
Terminal Type And Quantity
2 threaded stud
-
Circuit Protection Type
overcurrent single location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Iii Storage Type
general purpose warehouse
-
Iii Arc Quenching Method
magnetic blowout
-
Mounting Surface To Terminal End Distance
2.611 inches nominal
-
Boss Height
0.140 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
-
Body Width
0.750 inches nominal
-
Body Length
2.500 inches nominal